$249.00
- Availability:
- In Stock
- Brand:
- Eco-Smart
This 8.0KW Smart Technology electric tankless water heater is configured for climates where incoming water temperatures are in the 65-77F range. The model ECO 8 is well suited for homes in the southern States , Lower Texas and Florida. Digital Temperature Control allows you to set your temperature up to 125 F. Designed for a maximum flow rate of 1.5 gpm
Before purchasing an ECOSMART, please ensure that your home has sufficient electrical capacity for your desired model, or that you have taken note of any upgrades that may be required.
Additional Information
Maximum Flow Rate Desired: You should consider the maximum flow rate you really need or use. See chart for flow rate guidelines for various hot water applications in the home. The average shower temperatures are between 98°F-105°F. The chart is based on a 220V input voltage and maximum flow rates are listed for various incoming water temperatures.
|
Inlet Water Temperature |
40°F | 45°F | 50°F | 55°F | 60°F | 65°F | 70°F | 75°F | 80°F |
| ECO 11 | 1.3 GPM | 1.3 GPM | 1.5 GPM | 1.7 GPM | 1.9 GPM | 2.0 GPM | 2.3 GPM | 2.7 GPM | 3.0 GPM |
| ECO 8 | .75 GPM | .80 GPM | 1.0 GPM | 1.2 GPM | 1.3 GPM | 1.4 GPM | 1.5 GPM | 2.0 GPM | 2.2 GPM |
| ECO 6 | .25 GPM | .40 GPM | .60 GPM | .75 GPM | 1.0 GPM | 1.2 GPM | 1.4 GPM | 1.5 GPM | 1.7 GPM |
If you typically use about 2.5 gallons per minute ( 1showers with water saver showerheads and hand sink) at the same time, find the 2.5 GPM on the chart or the number closes to it. If the number is highlighted in GREEN, that means it's the correct model for you. It it's highlighted in YELLOW, that means you can get by with it. If it's highlighted in RED, you should consider a model a step or two up.
|
CHART TO THE LEFT REFLECTS TEMPERATURE RISE AT DIFFERENT FLOW RATES FOR THE DIFFERENT MODELS. |
Specifications
| Voltage single phase | 208/240V |
| ECO 8 | 8.2 KW 40.0A |
| HZ | 50/60 |
| Pipes fittings | 1/2" compression union |
| Dimensions | 12.9"x 6.5"x 9.9" |
| Weight | 7 LBS. |
| Tubing | Stainless steel |
| Protection | Thermal automatic |
| Temp control | Max setting to 125°f |
| Activation flow | .25 GPM |
| Supplied wire | 6 gauge |
| Energy efficiency | 99.8 |
| Certification | UL 499/CSA |
Electrical Requirements
Before purchasing an ECOSMART, please ensure that your home has sufficient electrical capacity for your desired model, or that you have taken note of any upgrades that may be required.
Please see the following chart for electrical requirements:
| Model |
Recommended Breaker |
Maximum Amperage @ 240 V |
Recommended Household Electrical Service |
Recommended Minimum Wire Gauge |
| ECO 27 | 3 x 40 AMPS | 112.5 AMPS | 200 AMPS | 3 x #8 AWG Copper |
| ECO 24 | 3 x 40 AMPS | 100 AMPS | 200 AMPS | 3 x #8 AWG Copper |
| ECO 21 | 3 x 40 AMPS | 87.5 AMPS | 200 AMPS | 3 x #8 AWG Copper |
| ECO 18 | 2 x 40 AMPS | 75.0 AMPS | 125 AMPS | 2 x #8 AWG Copper |
| ECO 16 | 2 x 40 AMPS | 66.6 AMPS | 125 AMPS | 2 x #8 AWG Copper |
| ECO 11 | 1 x 60 AMPS | 58.0 AMPS | 100 AMPS | 1 x #6 AWG Copper |
| ECO 8 | 1 X 40 AMPS | 34.0 AMPS | 100 AMPS | 1 X #10 AWG Copper |
| ECO 6 | 1 X 25 AMPS | 25.0 AMPS | 100 AMPS | 1 X #10 AWG Copper |
| ECO 5.5 | 1 X 25 AMPS | 22.9 AMPS | 100 AMPS | 1 X 10 AWG Copper |
Breaker size and wire gauge must meet all applicable local, state, provincial, and national electrical codes for your area - these are only guidelines that will apply to most installations. Some codes require use of electrical sub-panel for installation, especially when heater is not mounted within line-of-sight of the main electrical panel. Wiring should be sized to maintain a voltage drop of less than 3% under load. Please consult your electrician for more details.
The above specifications are only guidelines. If your home is already equipped with a large number of electrical appliances, you may require a larger electrical service than the one recommended above. Please consult an electrician before placing an order.
If your home does not have the minimum household electrical service as specified for your desired model, you can still purchase an ECOSMART tankless water heater, however, upgrades to your electrical service will likely be required. It is recommended that you consult your certified electrician for a quote, prior to purchasing.
| Power Consumption | |
|---|---|
| Watts | 8000 |